products Transformer Testing Equipment

new TTR 2796[ Transformer Turns Ratio Meter, 250 V ]
A close collaboration with major transformer manufacturers has lead to the new Tettex 2796 Transformer Turns Ratio Meter. It combines mobility and user friendly handling with unmatched accuracy of up to 0.03%. The higher test voltage of 250V together with the high precision assures authentic results especially on large power transformers. Advanced analysis features like trending allow the user to detect problems at an early stage. The automatic winding connection identification feature aids to find the correct transformer configuration. With the optional arbitrary phase shift software special transformers with irregular vector groups can also be measured. During production and also in the field the TTR 2796 is a highly valued diagnostic instrument. Within half a minute after connection the measurement cables to the terminals of the transformer, the voltage ratio, turns ratio, ratio deviation, exitation current and phase deviation are displayed.
product brochure

TTR 2795[ Transformer Turns Ratio Meter, 100 V ]
On-site testing of turns ratio is an important basic measurement for power transformer diagnosis. It helps to detect faulty transformer windings as well as defective tap changer positions. The simple ratio of turns or voltage and the related ratio error is not sufficient to detect all possible failures of a power transformer winding. The excitation current and the phase angle between primary and secondary windings give additional information about the winding condition. The TTR 2795 provides all these measurements in one compact instrument.
product brochure

2285d[ Transformer Test System ]
The 2285 is a computer controlled test system for power transformers. The system performs automated measurement of: Turns ratio Winding resistance Heat run tests are supported by: - Cold resistance - Temperature mesurement and supervision during temperature rise - Cooling curve - Extrapolation There are up to 18 resistance measuring channels and up to 24 temperature measuring channels available. Automated tap changer control is supported. The test point selector and the two powerfull supplies enable measurements at various test configurations on transformers with up to 3 winding systems with 3 phases.
product brochure

TMS 580 [ Transformer Measuring Sytem ]
The TMS 580 is a computer controlled high precision measuring system for power transformers. The system has distinguished itself in the rugged environment of the transformer test facility. The design ensures that its control and instrumentation function circuits remain unaffected by interference fields. The system performs automated measurement of:
Load loss measurement No-load loss measurement Heat run Induced voltage test Zero sequence measurement
There is also a Wattmeter function to perform quick and easy measurements without any additional calculations. The measuring data are accessible from other host systems for further processing.
product brochure

RVM 5462 [ Recovery Voltage Meter ]
The Recovery Voltage Method is based on established knowledge: the phenomenon of the polarization of oil/paper impregnated insulation. By this method, insulation condition is established by tracing the polarization spectrum from the results of the recovery voltage measurements. The instrument, the Recovery Voltage Meter type RVM 5462 effectively completes the range of the conventional insulation diagnosis methods, e.g. dissipation factor, partial discharge measurements, oil analysis, and so on.
product brochure

MiDAS 2880, 2881[ Mobile Insulation Diagnosis & Analysing System ]
Periodic maintenance and inspection of high voltage insulation losses is performed on power transformers, bushings, motors, generators, etc. The MIDAS 2880 is the perfect tool for onsite measurements especially in the harsh electrical environments experienced in substations and other field locations. To analyse condition and quality of high voltage insulation systems the system performs automated measurement of: - Dissipation Factor (tan δ) and Power Factor (cos φ) - Short Circuit Impedance and Excitation Current - Additional measuring capabilities like Capacitance, Quality Factor, Frequency, Voltage, Current, Power, Losses, Impedance, Inductance, Reactance, Spectrum Analyser, Digital Scope and Data Logger - Turns ratio, voltage ratio, phase displacement (optional) - Frequency response (optional)
product brochure

FRA 5310 [ Frequency Response Analyser ]
The FRA 5310 is a diagnosis instrument for the detection of mechanical distortions of transformer winding. These distortions can be caused by electro-dynamical forces which appear during short-circuits or by transportation damages during movement. The Sweep Frequency Response Analysis method is based on winding transfer function measured in a wide range of frequency. The system records the transformers “frequency response fingerprint”. Even small winding movements or distortions will cause legible change of transfer curve, which can be detected A powerful, easy-to-use operation and analysis Windows software runs on this touch screen controlled measuring instrument. Special active measuring probes minimise the influence of test object connecting and earthing which results in reproducible measurements.
product brochure

contact us
|